Inserting a sleeve in chimney in Kiev topical issue. How proizvezti gilzovku chimney. Avoid errors inserting a sleeve in chimney that can lead to undocking sleeve or tube to close the channel, not allowing complete installation - you can learn from this article, or in consultation with our specialist. To say that inserting a sleeve in chimney - it's just - so not quite tell the truth. Because, of course, for the technically literate and "armless" person is quite feasible task (with due study of the issue). It is for that person and is our article. If the information provided is not enough - you can learn more by calling a free consultation on our website. Of course, it is better to attend gilzovkoy chimney prior to the interior decoration of the building, but also in the subsequent steps possible to perform gilzovku brick chimney without destroying the "beauty" - tiles, wallpaper and so on. D. If funds permit - can be trusted gilzovanie by specialists from our company. What really is not worth saving, so it's on the thickness and grades of stainless steel. Certainly the best for solid fuel is stainless steel grade AISI 321 (korozionno- and heat-resistant), and for gas AISI 316 L (acid-resistant). Only those stainless steel close the question mark flues forever.

 

Inserting a sleeve in chimney. It is the compelled need or part of progress?

Builders, civil engineering firms and owners of private cottages ask a question, whether there is a need to insert a stainless steel sleeve in chimney. And, as a rule, everyone answers in the affirmative. And inserting a stainless steel sleeve is necessary both for gas coppers, and for the solid propellant ones. As it is necessary to protect a flue from destruction by acid condensate, stainless steel has to be acid resistant. Inserting a sleeve in chimney for a fireplace or a solid propellant copper differs in that steel has to be acid and heat-resistant.
Inserting a sleeve in chimney will also prevent hit of carbon monoxide to the room through a bricklaying.
So, to insert a sleeve or not? We answer "Yes".
1.The fluemetal thicknessof 1 mm(AISI321,1.4541).
Elements Diameter in mm., The price on the inner diameter in euro.
100 110 120 130 140 150 160 180 200 220 250 280 300
Tube 1 meter 16 17 19 19 23 23 23 26 28 31 35 44 47
Tube0,5 meter 10 11 11 12 14 14 14 16 17 19 21 27 29
Turn∟90 15 15 16 16 17 19 20 22 24 25 28 34 37
Turn∟45 11 11 11 11 13 14 15 15 17 17 20 24 26
Wye ∟90 23 26 29 30 32 33 35 37 40 44 50 62 66
Wye ∟45 32 33 35 37 39 41 43 48 53 59 67 80 89
Revision 15 16 17 18 19 20 21 23 26 30 32 40 42
Damper tube 17 19 21 22 24 26 27 30 33 36 41 48 51
What nuances and requirements is it necessary to consider for inserting a sleeve in chimney?
The first is diameter of a sleeve. It has to be equal to exhaust outlet of the heating device.
If it is a powerful copper 180 mm, average power 150 mm, a chimney fire chamber 200 mm.
Diameter of an exhaust outlet is specified in the passport of the heating device. Or it can be measured independently a caliper.
What can you do if you have the squared brick channel, which doesn't allow to mount a round chimney pipe? In this situation you can install oval pipe, that will allow to use the available channel and to keep the useful section of a flue. Our firm will make any sections of oval flues according to your specification.
For solid propellant and gas coppers it is necessary to provide a tee with a window and the device for a condensate drain at an angle 45 or 87 degrees.
So we approached the most important, responsible and difficult moment. It is installation of a sleeve of a flue.
Previously before the order of a flue, it is necessary to make inspection of the brick channel and to execute necessary measurements. The channel needs to be illuminated on all length by a powerful lamp. It is necessary to define, whether there are in the channel ledges of fittings, cement, shift or narrowing of the channel. According to the general rule the section of the channel needs to be reduced by 20 mm for convenient installation. For example, if there is a canal of 200200 mm, the pipe with a diameter of 180 mm will be located in it. (We speak about the closed canal to which the pipe moves from above on the channel). If the channel open, the pipe moves sideways and it is more convenient to mount it. There is an opportunity to put collars for fastening of a pipe.
At an exit from bricklaying to a roof it is necessary to mount the termination of a flue. It is a plate with a round or oval opening which centers a pipe in the channel and excludes hit of rainfall to the channel. On a pipe for a solid propellant copper it is necessary to mount a cap. For gas coppers a nozzle on flues are forbidden because of strong condensate frosting.
At an exit from bricklaying to a roof it is necessary to mount the termination of a flue. It is a plate with a round or oval opening which centers a pipe in the channel and excludes hit of rainfall to the channel. On a pipe for a solid propellant copper it is necessary to mount a cap. For gas coppers a nozzle on flues are forbidden because of strong condensate frosting. If near a flue there is a ventilating channel and all channels is planned to cover with the general cap, it needs to be made an opening and to remove a flue above a cap. If one does not make it, it is possible hit of a smoke in ventilation and, respectively, existence of an unpleasant smell in rooms.
So, the sleeve is inserted into a brick flue; the tube for removal of condensate is connected and removed in separate capacity; the gas or solid propellant copper is connected; the waterproofing is executed on the roof. At last, we check draft. We light a copper, a fireplace and we enjoy heat!